High-Quality 1500kw to 2000kw Diesel Generators from China Suppliers - Factory Direct Yuchai Engine Power Solutions
Video Demonstration
Standard Features
| Feature Description | Standard |
|---|---|
| Engine (Yuchai ENGINE) | ● |
| Radiator 50°C max, fans are driven by belt | ● |
| 24V charge alternator | ● |
| Alternator: single bearing alternator IP23 | ● |
| insulation class H/H | ● |
| Standard auto control system | ● |
| One set of air filter, fuel filter, oil filter | ● |
| Main line circuit breaker / ACB | ● |
| Base fuel tank | ● |
| Two 24V batteries, rack and cable | ● |
| Exhaust system (Ripple flex exhaust pipe) | ● |
| Exhaust siphon, flange, muffler | ● |
| User manual | ● |
| Battery charger | ● |
| Water heater | ● |
Weichai diesel generator set type spectrum
| Model Number | Output Power (KW/KVA) | Rated Current | Diesel Model | No. of cylinders | Bore x Stroke (mm) | Displacement (L) | Fuel consumption at rated working condition | Dimensions of set (mm) | Weight of set | Rated Voltage (V) | Frequency | Phase/Wire | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PRP | ESP | ||||||||||||
| SP20GF | 20KW/25KVA | 22KW/27.5KVA | 36A | YCDV254FHZ-25 | 4 | 89*100 | 2.5L | ≤200g/kw.h | 1500×730×1300 | 680kg | 220/380 | 50Hz | Three-phase four-wire |
| SP25GF | 25KW5/31.25KVA | 27.5KW/34.4KVA | 45A | YCDV254FHZ-35 | 4 | 89*100 | 2.5L | ≤200g/kw.h | 1600*650*1140 | 680kg | 220/380 | 50Hz | Three-phase four-wire |
| SP30GF | 30KW/37.5KVA | 33KW/41.25KVA | 54A | YC4R55-D39 | 4 | 87*103 | 2.4L | ≤225g/kw.h | 1000*650*1000 | 890kg | 220/380 | 50Hz | Three-phase four-wire |
| SP40GF | 40KW/50KVA | 45KW/55KVA | 72A | YC4FA75-D30 | 4 | 108*115 | 4.2L | ≤205g/kw.h | 1650*650*1000 | 1000kg | 220/380 | 50Hz | Three-phase four-wire |
| SP50GF | 50KW/62.5KVA | 55KW/68.75KVA | 90A | YC4D90-D39 | 4 | 108*115 | 4.2L | ≤205g/kw.h | 1750*850*1400 | 1100kg | 220/380 | 50Hz | Three-phase four-wire |
| SP60GF | 60KW/75KVA | 65KW/82.5KVA | 108A | YC4D100-D39 | 4 | 108*115 | 4.2L | ≤205g/kw.h | 2400*900*1300 | 1300kg | 220/380 | 50Hz | Three-phase four-wire |
| SP64GF | 64KW/80KVA | 70KW/88KVA | 115A | YC4A115-D3A | 4 | 108*115 | 4.2L | ≤205g/kw.h | 1600*700*1500 | 1320kg | 220/380 | 50Hz | Three-phase four-wire |
| SP80GF | 80KW/100KVA | 90KW/110KVA | 144A | YC4A140-D3A | 4 | 108*132 | 4.8L | ≤210g/kw.h | 1800*760*1500 | 1400kg | 220/380 | 50Hz | Three-phase four-wire |
| SP90GF | 90KW/112.5KVA | 100KW/123.75KVA | 162A | YC4A155-D3A | 4 | 108*132 | 4.8L | ≤210g/kw.h | 2500*900*1500 | 1340kg | 220/380 | 50Hz | Three-phase four-wire |
| SP100GF | 100KW/125KVA | 120KW/137.5KVA | 180A | YC4A180-D31 | 4 | 108*132 | 4.8L | ≤210g/kw.h | 2500*1000*1600 | 1430kg | 220/380 | 50Hz | Three-phase four-wire |
| SP120GF | 120KW/150KVA | 140KW/165KVA | 216A | YC6A205-D30 | 6 | 108*132 | 7.2L | ≤200g/kw.h | 2500*1000*1600 | 1600kg | 220/380 | 50Hz | Three-phase four-wire |
| SP140GF | 140KW/175KVA | 150KW/192.5KVA | 252A | YC6A230-D30 | 6 | 108*132 | 7.2L | ≤200g/kw.h | 2500*1000*1600 | 2500kg | 220/380 | 50Hz | Three-phase four-wire |
| SP150GF | 150KW/187.5KVA | 160KW/206.25KVA | 270A | YC6A245-D30 | 6 | 108*132 | 7.2L | ≤200g/kw.h | 2900*1200*1400 | 2500kg | 220/380 | 50Hz | Three-phase four-wire |
| SP160GF | 160KW/200KVA | 180KW/220KVA | 288A | YC6A275-D30 | 6 | 108*132 | 7.2L | ≤200g/kw.h | 3000*1200*1400 | 2500kg | 220/380 | 50Hz | Three-phase four-wire |
| SP200GF | 200KW/250KVA | 220KW/275KVA | 360A | YC6MK350-D30 | 6 | 123*145 | 10.3L | ≤195g/kw.h | 3000*1100*1700 | 2140kg | 220/380 | 50Hz | Three-phase four-wire |
| SP250GF | 250KW/312.5KVA | 270KW/343.75KVA | 450A | YC6MK420-D30 | 6 | 123*145 | 10.3L | ≤192g/kw.h | 3000*1100*1700 | 2500kg | 220/380 | 50Hz | Three-phase four-wire |
| SP300GF | 300KW/375KVA | 330KW/412.5KVA | 540A | YC6K500-D30 | 6 | 129*155 | 12.16L | ≤192g/kw.h | 3100*1100*1800 | 2800kg | 220/380 | 50Hz | Three-phase four-wire |
| SP320GF | 320KW/400KVA | 330KW/440KVA | 576A | YC6K520-D30 | 6 | 129*155 | 12.16L | ≤192g/kw.h | 3100*1100*1900 | 3330kg | 220/380 | 50Hz | Three-phase four-wire |
| SP350GF | 350KW/43.75KVA | 400KW/481.25KVA | 630A | YC6K570-D30 | 6 | 129*165 | 12.16L | ≤192g/kw.h | 3100*1100*1900 | 3300kg | 220/380 | 50Hz | Three-phase four-wire |
| SP400GF | 400KW/500KVA | 440KW/550KVA | 720A | YC6T660-D31 | 6 | 145*165 | 13.6L | ≤195g/kw.h | 3950*1100*2000 | 4200kg | 220/380 | 50Hz | Three-phase four-wire |
| SP450GF | 450KW/440KVA | 500KW/484KVA | 810A | YC6TD780-D31 | 6 | 145*165 | 19.6L | ≤195g/kw.h | 4000*1430*2050 | 4100kg | 220/380 | 50Hz | Three-phase four-wire |
| SP500GF | 500KW/625KVA | 550KW/687.5KVA | 900A | YC6TD840-D31 | 6 | 152*180 | 19.6L | ≤195g/kw.h | 4000*1430*2050 | 4100kg | 220/380 | 50Hz | Three-phase four-wire |
| SP550GF | 550KW/687.5KVA | 600KW/756.25KVA | 990A | YC6TD900-D30 | 6 | 152*180 | 19.6L | ≤195g/kw.h | 4000*1430*2050 | 4100kg | 220/380 | 50Hz | Three-phase four-wire |
| SP600GF | 600KW/750KVA | 660KW/825KVA | 1080A | YC6C1020-D31 | 6 | 200*210 | 39.58L | ≤195g/kw.h | 4700*1500*2050 | 7500kg | 220/380 | 50Hz | Three-phase four-wire |
| SP650GF | 650KW/812.5KVA | 710KW/893.75KVA | 1170A | YC6C1070-D31 | 6 | 200*210 | 39.58L | ≤195g/kw.h | 4700*1500*2050 | 7500kg | 220/380 | 50Hz | Three-phase four-wire |
| SP730GF | 730KW/912.5KVA | 800KW/1003.75KVA | 1314A | YC6C1220-D31 | 6 | 200*210 | 39.58L | ≤195g/kw.h | 4700*1500*2050 | 7500kg | 220/380 | 50Hz | Three-phase four-wire |
| SP800GF | 800KW/1000KVA | 900KW/1100KVA | 1440A | YC6C1320-D31 | 6 | 200*210 | 39.85L | ≤195g/kw.h | 4700*1500*2050 | 7500kg | 220/380 | 50Hz | Three-phase four-wire |
| SP900GF | 900KW/1125KVA | 1000KW/1237.5KVA | 1620A | YC6C1520-D31 | 6 | 200*210 | 39.58L | ≤195g/kw.h | 4750*1870*2480 | 8500kg | 220/380 | 50Hz | Three-phase four-wire |
| SP1000GF | 1000KW/1250KVA | 1100KW/1375KVA | 1818A | YC12VC1680-D31 | 12 | 200*210 | 78.17L | ≤196g/kw.h | 6500*2300*2600 | 13350kg | 220/380 | 50Hz | Three-phase four-wire |
| SP1200GF | 1200KW/1500KVA | 1350KW/1650KVA | 2160A | YC12VC2070-D31 | 12 | 200*210 | 79.17L | ≤196g/kw.h | 6500*2300*2600 | 13350kg | 220/380 | 50Hz | Three-phase four-wire |
| SP1350GF | 1350KW/1687.5KVA | 1500KW/1856.25KVA | 2430A | YC12VC2270-D31 | 12 | 200*210 | 79.17L | ≤196g/kw.h | 6500*2300*2600 | 13350kg | 220/380 | 50Hz | Three-phase four-wire |
| SP1500GF | 1500KW/1875KVA | 1600KW/2062.5KVA | 2700A | YC12VC2510-D31 | 12 | 200*210 | 79.17L | ≤196g/kw.h | 6500*2300*2600 | 13350kg | 220/380 | 50Hz | Three-phase four-wire |
| SP1700GF | 1700KW/2125KVA | 1800KW/2337.5KVA | 3060A | YC12VC2700-D31 | 12 | 200*210 | 79.17L | ≤196g/kw.h | 7500*2300*2800 | 15350kg | 220/380 | 50Hz | Three-phase four-wire |
| SP1800GF | 1800/KW2250KVA | 2005KW/2475KVA | 3609A | YC16VC3000-D31 | 16 | 200*210 | 81.3L | ≤196g/kw.h | 8000*2400*2850 | 18620kg | 220/380 | 50Hz | Three-phase four-wire |
| SP2000GF | 2000KW/2500KVA | 2205KW/2750KVA | 3969A | YC16VC3300-D31 | 16 | 200*210 | 81.3L | ≤196g/kw.h | 8000*2400*2850 | 18620kg | 220/380 | 50Hz | Three-phase four-wire |
| SP2200GF | 2200KW/2750KVA | 2405KW/3025KVA | 4329A | YC16VC3600-D31 | 16 | 200*210 | 81.3L | ≤196g/kw.h | 8000*2400*2850 | 18620kg | 220/380 | 50Hz | Three-phase four-wire |
| SP2430GF | 2430KW/3037.5KVA | 2673KW/3341.25KVA | 4811A | YC16VC4000-D31 | 16 | 200*210 | 81.3L | ≤196g/kw.h | 8000*2400*2850 | 18620kg | 220/380 | 50Hz | Three-phase four-wire |
Frequently Asked Questions
What is the rating power range of Yuchai diesel engines?
Yuchai diesel engines for speedboats, cargo ships, passenger ships, and fishing vessels have a rating power from 32kW to 2426.6kW. For generator sets, the rating power extends from 32kW to 3600kW.
Which alternator brands can be paired with these diesel generator sets?
You can optionally choose international primary brands such as Stanford, Leroy Somer, and others. The alternators feature customizable colors and global joint insurance policies.
What are the main features of the intelligent protection controller?
The genset is equipped with the British Deep Sea DSE7320 intelligent protection controller. It monitors speed, frequency, and oil pressure, provides system protection, automatically starts after a power failure, and supports operations in multiple languages including Chinese, English, Spanish, and Russian.
Can the alternator be customized for harsh working environments?
Yes. Depending on the operating conditions, the alternator can be equipped with anti-condensation heating, a high-temperature resistance design, and a wind and sand resistance design.
Where are Yuchai and Weichai diesel generator sets typically applied?
They are widely used as standby emergency power sources in hospitals, factories, buildings, mines, schools, hotels, aquaculture, data centers, communications, and petrochemical industries.
What standard features are included with the generator set?
Standard features include the Yuchai engine, radiator (50°C max), 24V charge alternator, single bearing alternator (IP23, insulation class H/H), standard auto control system, base fuel tank, two 24V batteries with rack and cable, standard filters, exhaust system (ripple flex pipe, siphon, flange, muffler), battery charger, and water heater.